 NEW SERIES
SV27 SENSING VALVES |
|
|
|

 * * *
EN 954-1, ISO 13849-1, & AS4202.1 (3/4 bodies only)
|
Load Holding Valve Non-Critical Functions as a
2-Way 2-Position Air Pilot- or Solenoid-Operated Check Valve
- For Category 2 applications.
- Air pilot- and solenoid-operated versions.
- Poppet construction for near zero leakage.
- Directly operated safety-rated force-guided
positive-break status switch (DPST).
- Holds a vertical load in the event of loss of air
pressure (and loss of electrical power with solenoid operated).
Control
Category 2
| Solenoid-operated |
Air
Pilot-operated |
Port |
| Model
Numbers* |
Model
Number* |
Size*
|
| SV27NA115408CSAA1A**
|
SV27NA115405ASAA
|
1/2 NPT*** |
| SV27NA115508CSAA1A**
|
SV27NA115505ASAA
|
3/4 NPT*** |
| SV27NA115608CSAA1A**
|
SV27NA115605ASAA
|
1 NPT*** |
| SV27NA117608CSAA1A**
|
SV27NA117605ASAA
|
1 NPT |
| SV27NA117708CSAA1A**
|
SV27NA117705ASAA
|
1-1//4 NPT |
| SV27NA117808CSAA1A**
|
SV27NA117805ASAA
|
1-1/2 NPT |
* For
BSPP thread type, replace N in the model number with a
D."
* * Solenoid pilot models above have 120V/60Hz solenoids.
Change 1A in model to 2A for 240V/60, 3A
for 24V/60, or 1D for 24 VDC.
Return
to Top of Page |
|

 * * * EN 954-1, ISO 13849-1, &
AS4202.1 (3/4 bodies only)
|
Redundant Load Holding Valve Functions as a 2-Way
2-Position Air Pilot- or Solenoid-Operated Check Valve
- For Category 3 applications.
- Air pilot- and solenoid-operated versions.
- Poppet construction for near zero leakage.
- Directly operated safety-rated force-guided
positive-break status switch (DPST).
- Holds a vertical load in the event of loss of air
pressure (and electrical power with solenoid operated models).
Control
Category 3
| Solenoid-operated |
Air
Pilot-operated |
Port |
| Model
Numbers* |
Model
Number* |
Size*
|
| SV27NA555408CSAA1A**
|
SV27NA555405ASAA
|
1/2 NPT*** |
| SV27NA555508CSAA1A**
|
SV27NA555505ASAA
|
3/4 NPT*** |
| SV27NA555608CSAA1A**
|
SV27NA555605ASAA
|
1 NPT*** |
| SV27NA557608CSAA1A**
|
SV27BA555405ASAA
|
1 NPT |
| SV27NA557708CSAA1A**
|
SV27BA555505ASAA
|
1-1//4 NPT |
| SV27NA557808CSAA1A**
|
SV27BA555605ASAA
|
1-1/2 NPT |
* For
BSPP thread type, replace N in the model number with a
D."
* * Solenoid pilot models above have 120V/60Hz solenoids.
Change 1A in model to 2A for 240V/60, 3A
for 24V/60, or 1D for 24 VDC.
Return
to Top of Page |
|

 * * * EN 954-1, ISO 13849-1, &
AS4202.1 (3/4 bodies only)
|
Low-Pressure Oil Load Holding Valve Functions as a
2-Way 2-Position Solenoid-Operated Check Valve
- Single units for Category 2 applications, and Dual units
for Category 3 applications; Category 3 unit shown).
- Poppet construction for near zero leakage.
- Directly operated safety-rated force-guided
positive-break status switch (DPST).
- Holds a vertical load in the event of loss of oil
pressure or electrical power.
- For use on air-oil systems. Max pressure 150 psig (10
bar).
Control
Category 2 and 3
| Model
Numbers* |
Single /
Dual |
Inlet
Port Size |
Control Category |
| SV27NA115HH8CSAA1D0002
|
Single |
SAE 12*** |
2 |
| SV27NA115KK8CSAA1D0002
|
Single |
SAE 16*** |
2 |
| SV27NA117LL8CSAA1D0002
|
Single |
SAE 20 |
2 |
| SV27NA117MM8CSAA1D0002
|
Single |
SAE 24 |
2 |
| SV27NA555HH8CSAA1D0002
|
Dual |
SAE 12*** |
3 |
| SV27NA555KK8CSAA1D0002
|
Dual |
SAE 16*** |
3 |
| SV27NA557LL8CSAA1D0002
|
Dual |
SAE 20 |
3 |
| SV27NA557MM8CSAA1D0002
|
Dual |
SAE 24 |
3 |
* 24
VDC only.
Return
to Top of Page |