|
 |

Schneider Electric Solutions
For . . . :: Motion Control ::
Machine Guarding :: Sensing
& Machine Control
MOTION
CONTROL
Altivar 31 Variable Speed
Drives Simply
Smart
Easy To Use . .
.
Ready to run The Altivar 31
parameters are factory set to run most applications out of the
box.
Autotuning Quickly adapts the drive
to the motor and provides dynamic performance.
Efficient Make simple adjustments to fit your
application, then monitor drive and motor details via the built in keypad
display.
:: Return to the top of the page
|
 |
MACHINE
GUARDING
Preventa XPSMC Safety Controllers
The XPSMC safety controllers can be used
for monitoring all of the different safety tasks for your applications in one
safety controller. The associated configuration software makes development of
the safety solution simple, using drag and drop techniques to configure the
safety system. Detailed diagnostics provides an indepth overview of the status
of the inputs and outputs, and identifies any faults and the cause.
XPSMC16Z and XPSMC32Z Safety Controllers
Conform To Category 4 per EN 954-1 and SIL 3 per IEC
61508
Features and Benefits Hardware
- Safety inputs - 16 or 32 safety inputs for flexible
multifunctional safety applications.
- Safety outputs - 6 safety semiconductor outputs, 2
safety relay outputs, with 2 relay contacts each (for a total of 4 relay
outputs), 1 output for muting indicators.
- Control outputs - 8 control outputs are used to supply
the safety inputs in order to detect faulty wiring or short circuits in the
wiring.
- Network Connections Available:
Features
and Benefits Configuration Software
- The wide device library of certified safety functions
simplifies the development of safety applications.
- Using the simple to use XPSMCWIN software, the
configuration can be developed without special training.
Features
and Benefits Diagnostics With PC and Software
- Using the diagnostics mode, the XPSMCWIN software
provides an exhaustive overview about the status of the safety functions.
- The status of the inputs, the safety devices and the
outputs are indicated by various colored indicators.
- A text message in a yellow frame clearly indicates the
kind and the location of a fault.
Features
and Benefits Diagnostics With LEDs in the Front Cover
- 6 LEDs indicate the status of the Controller.
- 8 LEDs indicate the status of the safety outputs.
- 16 or 32 LEDs indicate the status of the safety inputs.
- Input / output errors are indicated by blinking of the
correspondent LED.
:: Return to the top of the page
Preventa XPS Safety Modules
The XPS safety modules feature
redundancy principle micro-processor based technology to provide advanced
functions, and a wide product range enabling easy selection of a module for
monitoring a safety function.
Range
Description Optimum Solutions
Monitoring of a single
safety function this solution provides the optimum answer for monitoring
a function such as:
- Emergency stop and switches
- Coded magnetic switches
- Enabling switch
- Sensing mats and edges
- Two-hand control
- Light curtains
- Zero speed
- Time delay
- Lifts
- Other applications on hydraulic and eccentric presses.
Removable terminal block
version modules.
 Safety Modules
:: Return to the top of the
page
Osisonic Ultrasonic Sensors
Ultrasonic sensors to detect any object
without adjusting: metal, plastic, powder, liquid, paste, glass,
transparent, granulated, absorbent, any colour . . .
Range Description
- 3 flat formats, from the mini (0.7 x 2 x 3 cm) to the
combined, multi-fixing (Ø18 or 24 mm centres)
- 4 standardized cylindrical formats: Ø12,
Ø18 and Ø30 mm
- Application specific Ø 30 mm analogue output and
Ø 30 mm stainless steel case versions
- Accessories:
- for fixing,
specifically for each format
- / for programming
sensors featuring remote adjustment
- / for connection,
using connectors
- Products suitable for use in difficult environments:
sealed sensors insensitive to dust, insensitive to background noise,
temperature compensated, resistive to chemical agents.
- Sensing distances from 6 mm to 8 m.
- Digital PNP or NPN (selectable) outputs, NO or NC
function, analogue output 4
20mA or 0
10V
- Supply voltage 12/24V, connection using connectors
Extra
Large XX Osisonic Range

:: Return to the top of the
page
SENSING & MACHINE CONTROL
Altistart 01 - ATS
01 The starting solution ...
Soft start units
and soft start - soft stop units for single phase or 3-phase asynchronous
motors from 0,37 to 75 kW
Extremely compact, the Altistart 01 combines simplicity (easy cabling, fast configuration...) and
efficiency; it reduces machine wear, minimizes
maintenance time, etc. With TeSys® Model U, the first motor
starter-controller, you benefit from a unique motor starter solution.
Applications
- Small Compressors, Fans
- Conveyors, Mats
- Washing Gantries
- Advanced Systems and Decentralized Architectures
Range
Description Single-phase 110 - 230 V - 3-phase 200... 480 V 50/60 Hz - 0,37
to 15 kW*
- Adjustable starting and deceleration times: 5 seconds
or
- 10 seconds
- Adjustable unjamming torque
- Integrated bypass contactor
- Simple dialogue by 2 LEDs
- Signalling on completion of starting
- 24 V integrated power supply (ATS01N2...).
- Boost function for difficult starting
conditions (ATS01N2...).
* Range
available up to 75 kW
::
Return to the top of the page
|
VICKERS-WARNICK P: 905-662-7737 or 800-263-6835 F:
905-662-9424 E: info@vickers-warnick.com www.vickers-warnick.com
|